[2026-08-04T12:38:14.456890+00:00] Inicio da analise FEM da estacao inferior. [2026-08-04T12:38:14.675528+00:00] Software: {'freecad': '1.1.3', 'gmsh': '4.15.0', 'calculix': 'This is Version 2.23'}. [2026-08-04T12:38:15.105239+00:00] Documento FEM criado: 1 solido, bases=['Face5', 'Face15'], topo=Face17, carga_operacional=True. [2026-08-04T12:38:15.817607+00:00] Gmsh concluiu: nos=2973, elementos=1302, volumes=1302. [2026-08-04T12:38:16.031346+00:00] Entrada CalculiX escrita: hillink_lower_station_fem.inp. [2026-08-04T12:38:16.206598+00:00] CalculiX stdout: ************************************************************ CalculiX Version 2.23, Copyright(C) 1998-2025 Guido Dhondt CalculiX comes with ABSOLUTELY NO WARRANTY. This is free software, and you are welcome to redistribute it under certain conditions, see gpl.htm ************************************************************ You are using an executable made on Fri Nov 7 12:06:17 UTC 2025 The numbers below are estimated upper bounds number of: nodes: 2973 elements: 2730 one-dimensional elements: 0 two-dimensional elements: 0 integration points per element: 4 degrees of freedom per node: 3 layers per element: 1 distributed facial loads: 0 distributed volumetric loads: 1 concentrated loads: 326 single point constraints: 414 multiple point constraints: 1 terms in all multiple point constraints: 1 tie constraints: 0 dependent nodes tied by cyclic constraints: 0 dependent nodes in pre-tension constraints: 0 sets: 5 terms in all sets: 9990 materials: 1 constants per material and temperature: 2 temperature points per material: 1 plastic data points per material: 0 orientations: 0 amplitudes: 3 data points in all amplitudes: 3 print requests: 1 transformations: 0 property cards: 0 STEP 1 Static analysis was selected Decascading the MPC's Determining the structure of the matrix: Using up to 8 cpu(s) for setting up the structure of the matrix. number of equations 8505 number of nonzero lower triangular matrix elements 257616 Using up to 8 cpu(s) for the stress calculation. Using up to 8 cpu(s) for the symmetric stiffness/mass contributions. Factoring the system of equations using the symmetric spooles solver Using 1 cpu for spooles. Using up to 8 cpu(s) for the stress calculation. Job finished [2026-08-04T12:38:16.206638+00:00] CalculiX stderr: [2026-08-04T12:38:16.337893+00:00] Resultado importado: Umax=0.337651388 mm, vonMises_max=3.13332822 MPa. [2026-08-04T12:38:16.494733+00:00] Validacao global: solved. [2026-08-04T12:38:16.498966+00:00] Resumo JSON: /Users/joaocosta/Hillink/analysis_results/hillink_lower_station_fem_summary.json. [2026-08-04T12:38:16.498972+00:00] Resumo Markdown: /Users/joaocosta/Hillink/analysis_results/hillink_lower_station_fem_summary.md.